Niti-S™ Biliary Slim™ M Stent

Hook and cross for conformability

Niti-S™ Biliary Slim™ M Stent

Niti-S™ Biliary Slim™ M Stent: 6Fr delivery system with tapered tip

Features:

  • Radiopaque marker: 3 (three) at both ends & 2 (two) in the middle
  • Handwoven Hook and Cross for conformability
  • Stent lengths up to 12 cm
  • Delivery system: 6Fr / 180cm (0.025 inch guidewire)
  • Stent size: Diameter 6,8mm / Length 4~12cm

Minimized Tissue Damage

Unlike Laser-Cut stents with sharp edges, Slim M’s braided structure minimizes unnecessary tissue irritation. The M-Type design reduces stent-induced stress, improving procedural outcomes and minimizing adverse events.

Minimized Tissue Damage

Shinkansen Tip Advantage

Minimal guidewire-tip gap which reduces procedural complications, particularly in second stenting scenarios. Prevents wire slipping, improving stability during insertion.

Enhanced passage through strictures and sharp angles: improving navigation in tight or complex anatomical structures.

Soft design for difficult cases to ensure better maneuverability through steep angles, improving success rates.

Improved Stricture-Puncture Capability reducing procedural challenges by minimizing wire slippage and improving wire control during difficult cases.

Versatile Deployment Options Based on Indication

The Niti-S™ Slim M Stent is designed to adapt to a wide range of clinical scenarios with precision and flexibility offering deployment versatility that supports your procedural strategy.

Stent-in-Stent (SIS)

Stent-in-Stent (SIS)

The Slim M Stent’s braided structure prevents stent compression or shortening during deployment reducing the risk of overlapping or shrinking. This makes second stenting more manageable and improves the stability of the stents.

Stent-by-Stent (SBS)

Ideal for hilar strictures, dual stents can be deployed simultaneously, reducing procedure time and improving success rates.

Easier guidewire access by maintaining separate guidewire channels ensures easier follow-up access for additional interventions.

Stent-by-Stent (SBS)

Malignant Biliary Obstruction

Manage complex biliary obstructions with multiple options.  The duo of ELRA™ Biliary RFA and Slim™ M stents allow physicians to treat with both conventional and advanced therapeutic options.  Combine them together to manage tissue in growth safely and efficiently.  The Slim™ M stents open cell design allows for easier rates of reintervention. ELRA™ temperature control and impedance monitoring ensures that only tissue is being treated during the biliary ablation.

Ordering Information

Code Stent Delivery
Diameter (mm) Length (cm) Profile (fr) Usable Length (cm)*
BN0604-6 6 4 6 180
BN0605-6 5
BN0606-6 6
BN0607-6 7
BN0608-6 8
BN0609-6 9
BN0610-6 10
BN0612-6 12
BND0804-6 8 4 6 180
BND0805-6 5
BND0806-6 6
BND0807-6 7
BND0808-6 8
BND0809-6 9
BND0810-6 10
BND0812-6 12

For inquiries or to place an order please contact us: